AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;
AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: It is possible that the NVD CVSS may not match that of the CNA. The most common reason for this is that publicly available information does not provide sufficient detail or that information simply was not available at the time the CVSS vector string was assigned.
NVD Analysts use publicly available information to associate vector strings and CVSS scores. We also display any CVSS information provided within the CVE List from the CNA.
Note: NVD Analysts have not published a CVSS score for this CVE at this time. NVD Analysts use publicly available information at the time of analysis to associate CVSS vector strings.
References to Advisories, Solutions, and Tools
By selecting these links, you will be leaving NIST webspace.
We have provided these links to other web sites because they
may have information that would be of interest to you. No
inferences should be drawn on account of other sites being
referenced, or not, from this page. There may be other web
sites that are more appropriate for your purpose. NIST does
not necessarily endorse the views expressed, or concur with
the facts presented on these sites. Further, NIST does not
endorse any commercial products that may be mentioned on
these sites. Please address comments about this page to [email protected].
AND
OR
*cpe:2.3:o:automationdirect:d0-06aa_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.72
OR
cpe:2.3:h:automationdirect:d0-06aa:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:automationdirect:d0-06ar_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.72
OR
cpe:2.3:h:automationdirect:d0-06ar:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:automationdirect:d0-06da_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.72
OR
cpe:2.3:h:automationdirect:d0-06da:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:automationdirect:d0-06dd1-d_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.72
OR
cpe:2.3:h:automationdirect:d0-06dd1-d:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:automationdirect:d0-06dd1_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.72
OR
cpe:2.3:h:automationdirect:d0-06dd1:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:automationdirect:d0-06dd2-d_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.72
OR
cpe:2.3:h:automationdirect:d0-06dd2-d:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:automationdirect:d0-06dd2_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.72
OR
cpe:2.3:h:automationdirect:d0-06dd2:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:automationdirect:d0-06dr-d_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.72
OR
cpe:2.3:h:automationdirect:d0-06dr-d:-:*:*:*:*:*:*:*
Added
CPE Configuration
AND
OR
*cpe:2.3:o:automationdirect:d0-06dr_firmware:*:*:*:*:*:*:*:* versions up to (excluding) 2.72
OR
cpe:2.3:h:automationdirect:d0-06dr:-:*:*:*:*:*:*:*
Added
CVSS V3.1
NIST AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Changed
Reference Type
https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-02 No Types Assigned
https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-02 Patch, Third Party Advisory, US Government Resource
Changed
Reference Type
https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03 No Types Assigned
https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03 Patch, Third Party Advisory, US Government Resource