I've been having the same issue, and have noted the same lack of loading of that particular setting.
So far, what I've got is that the caching of settings is at least partly to blame.
If you check out how it's implemented, disabling the cache has no effect on future calls to values (i.e. if caching is enabled and something is accessed during that time, then it will always be cached).
https://referencesource.microsoft.com/#mscorlib/system/AppContext/AppContext.cs
This doesn't seem to be an issue for most of the settings, but for some reason the UseLegacyPathHandling and BlockLongPaths settings are getting cached by the time I can first step into the code.
At this time, I don't have a good answer, but if you need something in the interim, I've got a highly suspect temporary fix for you. Using reflection, you can fix the setting in the assembly init. It writes to private variables by name, and uses the specific value of 0 to invalidate the cache, so it's a very delicate fix and not appropriate for a long term solution.
That being said, if you need something that 'just works' for the time being, you can check the settings, and apply the hack as needed.
Here's a simple example code. This would be a method you'll need in your test class.
[AssemblyInitialize]
public static void AssemblyInit(TestContext context)
{
// Check to see if we're using legacy paths
bool stillUsingLegacyPaths;
if (AppContext.TryGetSwitch("Switch.System.IO.UseLegacyPathHandling", out stillUsingLegacyPaths) && stillUsingLegacyPaths)
{
// Here's where we trash the private cached field to get this to ACTUALLY work.
var switchType = Type.GetType("System.AppContextSwitches"); // <- internal class, bad idea.
if (switchType != null)
{
AppContext.SetSwitch("Switch.System.IO.UseLegacyPathHandling", false); // <- Should disable legacy path handling
// Get the private field that is used for caching the path handling value (bad idea).
var legacyField = switchType.GetField("_useLegacyPathHandling", System.Reflection.BindingFlags.Static | System.Reflection.BindingFlags.NonPublic);
legacyField?.SetValue(null, (Int32)0); // <- caching uses 0 to indicate no value, -1 for false, 1 for true.
// Ensure the value is set. This changes the backing field, but we're stuck with the cached value for now.
AppContext.TryGetSwitch("Switch.System.IO.UseLegacyPathHandling", out stillUsingLegacyPaths);
TestAssert.False(stillUsingLegacyPaths, "Testing will fail if we are using legacy path handling.");
}
}
}