After some searching I think I have found answers to what I was looking for, however please add additional answers if you happen to have a reference to a standard containing AT&W
.
Hayes documentation
While I have not found any manual for the Smartmodem 1200 or Smartmodem 2400 modems,
I found a paper called Technical Reference for Hayes Modem Users
which says the following about AT&W
:
&W - Write Active Profile to Memory
The &W command stores certain command options and S-register values into
one of the modem's two nonvolatile stored profile memory locations. The
command options and register values stored depend on the particular
modem. These are indicated in the user documentation for your modem.
In addition, the AT speed and parity are stored, according to the values
used at the time the command is issued.
------------------------------------------------------------------------
&W0 Store the Active Profile into Stored Profile 0
&W1 Store the Active Profile into Stored Profile 1
------------------------------------------------------------------------
I assume this covers more or less all modems made by Hayes, so I think this probably is the most official reference I get.
Other standards
An (older) alternative specification to V.25ter/V.250 is TIA/EIA-602 with title "Data Transmission Systems and Equipment - Serial Asynchronous Automatic Dialing and Control". According to Information On Hayes command set:
TIA/EIA-602 is almost identical to the
data-specific commands found in the
Smartmodems 1200 and Smartmodem 2400
but the specification is not including everything,
TIA/EIA-602 is also referred to as the "Minimal AT Command Set".
According to Frank Durda's AT Ampersand-Prefixed Command Set Reference
The EIA/TIA-602 standard only
specifies three AT commands with
ampersand prefixes: &C, &D and &F. All
other AT commands with ampersand
prefixes derive either from the Hayes
Smartmodem 2400, Hayes Ultra 14,400 or
are proprietary features of other
makers.
Which I then interpret to mean that either Hayes Smartmodem defines AT&W
but EIA/TIA-602 does not import it (most likely) or that it was introduced after the creation of EIA/TIA-602 at some point (no so likely).
Anyone that has access to an original Hayes Smartmodem manual?