Welcome to OGeek Q&A Community for programmer and developer-Open, Learning and Share
Welcome To Ask or Share your Answers For Others

Categories

0 votes
334 views
in Technique[技术] by (71.8m points)

c# - Modify endpoint ReaderQuotas programmatically

I have a dynamic client to a service. How can i change the ReaderQuotas property of it's endpoint binding?

I tried like this but it doesn't work ...

 DynamicProxyFactory factory = new DynamicProxyFactory(m_serviceWsdlUri);

 foreach (ServiceEndpoint endpoint in factory.Endpoints)
 {
     Binding binding =  endpoint.Binding;

     binding.GetProperty<XmlDictionaryReaderQuotas>(new BindingParameterCollection()).MaxArrayLength = 2147483647
     binding.GetProperty<XmlDictionaryReaderQuotas>(new BindingParameterCollection()).MaxBytesPerRead =2147483647;
     binding.GetProperty<XmlDictionaryReaderQuotas>(new BindingParameterCollection()).MaxDepth = 2147483647;
     binding.GetProperty<XmlDictionaryReaderQuotas>(new BindingParameterCollection()).MaxNameTableCharCount = 2147483647;
     binding.GetProperty<XmlDictionaryReaderQuotas>(new BindingParameterCollection()).MaxStringContentLength = 2147483647;
   }

Even after doing this the ReaderQuotas values remain the default ones.

I also tried like this and still doesn't work:

     DynamicProxyFactory factory = new DynamicProxyFactory(m_serviceWsdlUri);

     foreach (ServiceEndpoint endpoint in factory.Endpoints)
     {
         System.ServiceModel.Channels.BindingElementCollection bec = endpoint.Binding.CreateBindingElements();

         System.ServiceModel.Channels.TransportBindingElement tbe = bec.Find<System.ServiceModel.Channels.TransportBindingElement>();

         tbe.MaxReceivedMessageSize = 2147483647;
         tbe.MaxBufferPoolSize = 2147483647;
         TextMessageEncodingBindingElement textBE = bec.Find<TextMessageEncodingBindingElement>();

         if (textBE != null)
         {

             textBE.ReaderQuotas.MaxStringContentLength = 2147483647;
             textBE.ReaderQuotas.MaxArrayLength = 2147483647;
             textBE.ReaderQuotas.MaxBytesPerRead = 2147483647;
             textBE.ReaderQuotas.MaxDepth = 2147483647;
             textBE.ReaderQuotas.MaxNameTableCharCount = 2147483647;

         }
   }

I need this so I can send more than 8kb to the service.

See Question&Answers more detail:os

与恶龙缠斗过久,自身亦成为恶龙;凝视深渊过久,深渊将回以凝视…
Welcome To Ask or Share your Answers For Others

1 Reply

0 votes
by (71.8m points)

Setting quotas on a BindingElement after the binding is created has no effect on that binding.

Edit (since you don't know what binding is used):

You can use reflection to set the property. Note you should make sure the Binding actually has the property before setting it. Not all bindings have this property. If you try to set it on a binding that doesn't support it, the example will throw an exception.

Binding binding = endpoint.Binding;

XmlDictionaryReaderQuotas myReaderQuotas = new XmlDictionaryReaderQuotas();
myReaderQuotas.MaxStringContentLength = _sanebutusablelimit_;
myReaderQuotas.MaxArrayLength = _sanebutusablelimit_;
myReaderQuotas.MaxBytesPerRead = _sanebutusablelimit_;
myReaderQuotas.MaxDepth = _sanebutusablelimit_;
myReaderQuotas.MaxNameTableCharCount = _sanebutusablelimit_;

binding.GetType().GetProperty("ReaderQuotas").SetValue(binding, myReaderQuotas, null);

Hope this helps you a bit.


与恶龙缠斗过久,自身亦成为恶龙;凝视深渊过久,深渊将回以凝视…