EDIT: https://github.com/somanuell/SoBrowserAction
Here is a screen shot of my work in progress.
The things I did:
1. Escaping from the protected mode
The BHO Registration must update the HKEY_LOCAL_MACHINESOFTWAREMicrosoftInternet ExplorerLow RightsElevationPolicy
key. See Understanding and Working in Protected Mode Internet Explorer.
I choose the process way because it's noted as "best practice" and is easier to debug, but the RunDll32Policy
may do the trick, too.
Locate the rgs
file containing your BHO registry settings. It's the one containing the upadte to the Registry Key 'Browser Helper Object'
. Add to that file the following:
HKLM {
NoRemove SOFTWARE {
NoRemove Microsoft {
NoRemove 'Internet Explorer' {
NoRemove 'Low Rights' {
NoRemove ElevationPolicy {
ForceRemove '{AE6E5BFE-B965-41B5-AC70-D7069E555C76}' {
val AppName = s 'SoBrowserActionInjector.exe'
val AppPath = s '%MODULEPATH%'
val Policy = d '3'
}
}
}
}
}
}
}
The GUID must be a new one, don't use mine, use a GUID Generator.
The 3
value for policy ensures that the broker process will be launched as a medium integrity process. The %MODULEPATH%
macro is NOT a predefined one.
Why use a macro?
You may avoid that new code in your RGS file, provided that your MSI contains that update to the registry. As dealing with MSI may be painful, it's often easier to provide a "full self registering" package. But if you don't use a macro, you then can't allow the user to choose the installation directory. Using a macro permits to dynamically update the registry with the correct installation directory.
How to make the macro works?
Locate the DECLARE_REGISTRY_RESOURCEID
macro in the header of your BHO class and comment it out. Add the following function definition in that header:
static HRESULT WINAPI UpdateRegistry( BOOL bRegister ) throw() {
ATL::_ATL_REGMAP_ENTRY regMapEntries[2];
memset( ®MapEntries[1], 0, sizeof(ATL::_ATL_REGMAP_ENTRY));
regMapEntries[0].szKey = L"MODULEPATH";
regMapEntries[0].szData = sm_szModulePath;
return ATL::_pAtlModule->UpdateRegistryFromResource(IDR_CSOBABHO, bRegister,
regMapEntries);
}
That code is borrowed from the ATL implementation for DECLARE_REGISTRY_RESOURCEID
(in my case it's the one shipped with VS2010, check your version of ATL and update code if necessary). The IDR_CSOBABHO
macro is the resource ID of the REGISTRY
resource adding the RGS in your RC file.
The sm_szModulePath
variable must contains the installation path of the broker process EXE. I choose to make it a public static member variable of my BHO class. One simple way to set it up is in the DllMain
function. When regsvr32
load your Dll, DllMain
is called, and the registry is updated with the good path.
extern "C" BOOL WINAPI DllMain(HINSTANCE hInstance, DWORD dwReason, LPVOID lpReserved) {
if ( dwReason == DLL_PROCESS_ATTACH ) {
DWORD dwCopied = GetModuleFileName( hInstance,
CCSoBABHO::sm_szModulePath,
sizeof( CCSoBABHO::sm_szModulePath ) /
sizeof( wchar_t ) );
if ( dwCopied ) {
wchar_t * pLastAntiSlash = wcsrchr( CCSoBABHO::sm_szModulePath, L'\' );
if ( pLastAntiSlash ) *( pLastAntiSlash ) = 0;
}
}
return _AtlModule.DllMain(dwReason, lpReserved);
}
Many thanks to Mladen Jankovi?.
How to lauch the Broker process?
One possible place is in the SetSite
implementation. It will be lauched many times, but we will deal with that in the process itself. We will see later that the broker process may benefit from receiving as argument the HWND for the hosting IEFrame. This can be done with the IWebBrowser2::get_HWND
method. I suppose here that your already have an IWebBrowser2*
member.
STDMETHODIMP CCSoBABHO::SetSite( IUnknown* pUnkSite ) {
if ( pUnkSite ) {
HRESULT hr = pUnkSite->QueryInterface( IID_IWebBrowser2, (void**)&m_spIWebBrowser2 );
if ( SUCCEEDED( hr ) && m_spIWebBrowser2 ) {
SHANDLE_PTR hWndIEFrame;
hr = m_spIWebBrowser2->get_HWND( &hWndIEFrame );
if ( SUCCEEDED( hr ) ) {
wchar_t szExeName[] = L"SoBrowserActionInjector.exe";
wchar_t szFullPath[ MAX_PATH ];
wcscpy_s( szFullPath, sm_szModulePath );
wcscat_s( szFullPath, L"" );
wcscat_s( szFullPath, szExeName );
STARTUPINFO si;
memset( &si, 0, sizeof( si ) );
si.cb = sizeof( si );
PROCESS_INFORMATION pi;
wchar_t szCommandLine[ 64 ];
swprintf_s( szCommandLine, L"%.48s %d", szExeName, (int)hWndIEFrame );
BOOL bWin32Success = CreateProcess( szFullPath, szCommandLine, NULL,
NULL, FALSE, 0, NULL, NULL, &si, &pi );
if ( bWin32Success ) {
CloseHandle( pi.hThread );
CloseHandle( pi.hProcess );
}
}
}
[...]
2. Injecting the IEFrame threads
It appears that this may be the most complex part, because there are many ways to do it, each one with pros and cons.
The broker process, the "injector", may be a short lived one, with one simple argument (a HWND or a TID), which will have to deal with a unique IEFrame, if not already processed by a previous instance.
Rather, the "injector" may be a long lived, eventually never ending, process which will have to continually watch the Desktop, processing new IEFrames as they appear. Unicity of the process may be guaranteed by a Named Mutex.
For the time being, I will try to go with a KISS principle (Keep It Simple, Stupid). That is: a short lived injector. I know for sure that this will lead to special handling, in the BHO, for the case of a Tab Drag And Drop'ed to the Desktop, but I will see that later.
Going that route involves a Dll injection that survives the end of the injector, but I will delegate this to the Dll itself.
Here is the code for the injector process. It installs a WH_CALLWNDPROCRET
hook for the thread hosting the IEFrame, use SendMessage
(with a specific registered message) to immediatly trigger the Dll injection, and then removes the hook and terminates. The BHO Dll must export a CallWndRetProc
callback named HookCallWndProcRet
. Error paths are omitted.
#include <Windows.h>
#include <stdlib.h>
typedef LRESULT (CALLBACK *PHOOKCALLWNDPROCRET)( int nCode, WPARAM wParam, LPARAM lParam );
PHOOKCALLWNDPROCRET g_pHookCallWndProcRet;
HMODULE g_hDll;
UINT g_uiRegisteredMsg;
int WINAPI WinMain( HINSTANCE hInstance, HINSTANCE, char * pszCommandLine, int ) {
HWND hWndIEFrame = (HWND)atoi( pszCommandLine );
wchar_t szFullPath[ MAX_PATH ];
DWORD dwCopied = GetModuleFileName( NULL, szFullPath,
sizeof( szFullPath ) / sizeof( wchar_t ) );
if ( dwCopied ) {
wchar_t * pLastAntiSlash = wcsrchr( szFullPath, L'\' );
if ( pLastAntiSlash ) *( pLastAntiSlash + 1 ) = 0;
wcscat_s( szFullPath, L"SoBrowserActionBHO.dll" );
g_hDll = LoadLibrary( szFullPath );
if ( g_hDll ) {
g_pHookCallWndProcRet = (PHOOKCALLWNDPROCRET)GetProcAddress( g_hDll,
"HookCallWndProcRet" );
if ( g_pHookCallWndProcRet ) {
g_uiRegisteredMsg = RegisterWindowMessage( L"SOBA_MSG" );
if ( g_uiRegisteredMsg ) {
DWORD dwTID = GetWindowThreadProcessId( hWndIEFrame, NULL );
if ( dwTID ) {
HHOOK hHook = SetWindowsHookEx( WH_CALLWNDPROCRET,
g_pHookCallWndProcRet,
g_hDll, dwTID );
if ( hHook ) {
SendMessage( hWndIEFrame, g_uiRegisteredMsg, 0, 0 );
UnhookWindowsHookEx( hHook );
}
}
}
}
}
}
if ( g_hDll ) FreeLibrary( g_hDll );
return 0;
}
3. Surviving Injection: "hook me harder"
The temporary loading of the Dll in the main IE process is sufficient to add a new button to the Toolbar. But being able to monitor the WM_COMMAND
for that new button requires more: a permanently loaded Dll and a hook still in place despite the end of the hooking process. A simple solution is to hook the thread again, passing the Dll instance handle.
As each tab opening will lead to a new BHO instantiation, thus a new injector process, the hook function must have a way to know if the current thread is already hooked (I don't want to just add a hook for each tab opening, that's not clean)
Thread Local Storage is the way to go:
- Allocate a TLS index in
DllMain
, for DLL_PROCESS_ATTACH
.
- Store the new
HHOOK
as TLS data, and use that to know if the
thread is already hooked
- Unhook if necessary, when
DLL_THREAD_DETACH
- Free the TLS index in
DLL_PROCESS_DETACH
That leads to the following code:
// DllMain
// -------
if ( dwReason == DLL_PROCESS_ATTACH ) {
CCSoBABHO::sm_dwTlsIndex = TlsAlloc();
[...]
} else if ( dwReason == DLL_THREAD_DETACH ) {
CCSoBABHO::UnhookIfHooked();
} else if ( dwReason == DLL_PROCESS_DETACH ) {
CCSoBABHO::UnhookIfHooked();
if ( CCSoBABHO::sm_dwTlsIndex != TLS_OUT_OF_INDEXES )
TlsFree( CCSoBABHO::sm_dwTlsIndex );
}
// BHO Class Static functions
// --------------------------
void CCSoBABHO::HookIfNotHooked( void ) {
if ( sm_dwTlsIndex == TLS_OUT_OF_INDEXES ) return;
HHOOK hHook = reinterpret_cast<HHOOK>( TlsGetValue( sm_dwTlsIndex ) );
if ( hHook ) return;
hHook = SetWindowsHookEx( WH_CALLWNDPROCRET, HookCallWndProcRet,
sm_hModule, GetCurrentThreadId() );
TlsSetValue( sm_dwTlsIndex, hHook );
return;
}
void CCSoBABHO::UnhookIfHooked( void ) {
if ( sm_dwTlsIndex == TLS_OUT_OF_INDEXES ) return;
HHOOK hHook = reinterpret_cast<HHOOK>( TlsGetValue( sm_dwTlsIndex ) );
if ( UnhookWindowsHookEx( hHook ) ) TlsSetValue( sm_dwTlsIndex, 0 );
}
We now have a nearly complete hook function:
LRESULT CALLBACK CCSoBABHO::HookCallWndProcRet( int nCode, WPARAM wParam,
LPARAM lParam ) {
if ( nCode == HC_ACTION ) {
if ( sm_uiRegisteredMsg == 0 )